E12 – Low Level Alarm Possible Cause

Solution

a) Water level below level switch longer than respective setpoint

- Repair or replace level sensor - Adjust setpoints through HMI - Inspect unit for any leaking and repair as necessary

E13 – N/A

Possible Cause

Solution

a) N/A

N/A

E14 – Conductivity Hold Watchdog (optional) Possible Cause

Solution

a) Chemical has been injecting longer than the respective setpoint without reaching the respective concentration setpoint

- Ensure system has enough chemical for dispensing - Repair or replace chemical pump - Inspect lines for obstruction - Adjust setpoints through HMI - Repair or replace conductivity sensor

E15 – Temperature Sensor Failure Possible Cause a) Temperature sensor not reading correctly.

Solution

Repair or replace as necessary

E16 – Conductivity Sensor Failure (optional) Possible Cause

Solution

a) Conductivity sensor not reading correctly.

- Repair or replace as necessary - Sensor not enabled is system settings