E11 – Cabinet Door Open Possible Cause

Solution

a) Cabinet door is detected as open when it is required to be close

- Close the door, ensuring the door is approximately 1/8”-1/4” away from the proximity sensor. - Ensure the door can close easily and not binding on a gasket or other part. - Replace proximity sensor

E12 – Low Level Alarm Possible Cause

Solution

a) Water level below level switch longer than respective setpoint

- Ensure water in sump is not excessively foamy. - Ensure no parts are in sump or blocking the drain port. - Inspect CyClean for any leaking and repair as necessary. - Adjust setpoint through HMI - Use alternate sensor port. - Replace level sensor.

E13 – N/A

Possible Cause

Solution

a) N/A

N/A

E14 – Conductivity Hold Watchdog (optional) Possible Cause

Solution

a) Chemical has been injecting longer than the respective setpoint without reaching the respective concentration setpoint

- Ensure system has enough chemical for dispensing - Repair or replace chemical pump - Inspect lines for obstruction - Adjust setpoints through HMI