DM-0018_CleanWorx™ CyClean™ 35_IOM_Rev1.2

Water Quality: None While there are no water quality requirements, hard water can lead to scaling which has the potential to damage stainless steel if not cleaned properly, can leave mineral residue on parts, or can reduce heating efficiency. Additionally, water quality requirements should be discussed with a chemical supplier to ensure there are no compatibility or quality concerns.

Drain – 2” FNPT or 2” Tri-Clamp Connection • Flowrate: 10 gpm •

Temperature: 185°F or maximum supply temperature, whichever is greater. The drain is gravity fed. Ensure the drain connection on the CyClean is sloped appropriately to the drain.

Exhaust – 4” Diameter Tube Connection • Flowrate: 250 cfm

The exhaust will remove the hot, wet moisture vapor from inside the CyClean before the wash recipe is complete. Failure to properly vent may result in drastically increased humidity levels surrounding the CyClean. A dedicated exhaust line with a direct connection outside the production area is recommended. For other integration options, such as using dampers or plumbing into an existing exhaust line is the responsibility of the end user and consulting a local contractor is recommended.

Electrical Supply •

460VAC, 3PH, 60Hz

60 Amp

2.3) Controls & Sensors NEMA 4X Polycarbonate control enclosure containing: 1. Operator touchscreen 2. PLC controller 3. Emergency stop switch 4. Alarm reset button 5. UL required schematics and documentation

Included Connections, Sensors, and Valves • Analog Input M12 Cable Connections

9

Powered by