4) Poor Cleaning

Possible Cause

Solution

a) Spray nozzle plugged b) Spray arm not rotating

Clean nozzle

- Check rotations and clean rotary bushing. Should rotate between 10-20 RPM. - Adjust temperature setpoint. - Consult with chemical supplier.

c) Temperature too low

d) Low pump pressure

- Pump running backwards. - Leaky seals drawing air.

e) Cycle time too short

Adjust cycle time

f) Stainer plugged

Clean strainer