FBC-0001.5 Sanitary Components Catalog (2022)

CIPGuard ® The CIPGuard is an accessory available for monitoring proof of rotation for rotating spray devices. The CIPGuard is installed centrally in the top of a tank head or tri-clamp port, and setup occurs via a connected PC to set rotation frequency and impact force parameters. When the unit is operating within set parameters, a digital PNP output signal can be sent to a connected PLC, confirming that the unit is within the rotation frequency and impact force parameters.

Image

Description Part #

Key Technical Data

Wetted Materials of Construction - PEEK

G 1 / 2 " Connection - use with welded sleeve

CIPGuard Sensor

053549

24V DC Supply Voltage

145 psi / 100 ° C max process temperature

Required for initial CIPGuard Sensor Setup or Parameter Adjustment

PC Interface Cable, CIPGuard

USB connection for PC x M12 Adapter

053544

Free PC setup software available at http://www.awh.eu

Required for initial CIPGuard Sensor Setup or Parameter Adjustment

CIPGuard Interface Cable, CIPGuard

053548

8 pin connection for CIPGuard Sensor x M12 Adapter

Wetter Materials of Construction- 316Lss

Hygienic Weld-In Sleeve, CIPGuard

G 1 / 2 " Connection - use with CIPGuard Sensor

N/A

053547

Can be welded directly onto vessel or onto tri-clamp cap

Angled M12 Connection

M12 Cable, Angled, 15 meters

052066

For use with CIPGuard Sensor

CIPGuard

Hygienic Weld Sleeve

Tank Wall

CIPGuard Installation Example

CIPGuard Wiring Diagram

87