BPB-0006_UltraFlow®_Brochure_Rev3.0

Advantages • Small Footprint. Space-saving design for installations with limited floor space. Fits through standard doorways with ease. • Wide Operating Range. The systems range from 2–45 gpm and 5–110 gpm and are able to clean small and large applications. • Self-Cleaning. Self-cleans without extra steps, and eliminates cross-contamination. •   Portable. Positioned on low-friction casters for easy movement between process suites. No expensive supply and return line installation required. • Water & Chemical Savings. The high turbulent flow rate and low water requirements for operation reduce the amount of water and chemicals needed for a complete clean. •   Low Outlets? No Problem. Returns solutions with entrained air to accommodate vessels with low and restricted outlets.

SaniTrend ® Cloud Reporting Software

Add SaniTrend ® Cloud Cleaning Reports (CR) software to your equipment to efficiently and automatically record and store critical data (e.g., temperature, conductivity). SaniTrend ® Cloud CR Insights+ records all critical data in easy-to-interpret cleaning records and additional insights like event logs, Overall Equipment Effectiveness (OEE) scoring, Preventive Maintenance (PM) Tracking, and more. The Insights+ edition also logs a full HMI Audit Trail and is 21 CFR Part 11 compliant for electronic records and signatures. Learn more at our website at sanimatic.com/sanitrendcloud/

UltraFlow Schematic

Eductor

Return to Separator

Plant Water Supply

PI

FE

CIP Supply

LE

Chemical

Wash

TE

CE

CE

TE

CIP Return

CIP Return

LE

Recirculation

Documentation

Standard • Operation and maintenance manuals • Recommended spare parts (RSP) list • Mechanical Bill of Materials (BOM) • Instrumentation calibration procedures • Material Test Reports (MTRs) • W eld maps and weld logs (including qualification and inspection records) • Inspection test results, reports and certificates • Component vendor documentation • As-built General Assembly (GA) drawings • As-built Process and Instrumentation Diagrams (P&ID) • As-built electrical drawings

Optional • Functional Specifications (FS) • Configuration Specification (CS) • Factory Acceptance Test (FAT) • Site Acceptance Test (SAT) • Installation and Operation Qualification (IQ/OQ) • Traceability matrix • Instrument data sheets • Cleaning and passivation certificate

• Borescope Inspection Video • Hydrostatic test certificate • Riboflavin spray coverage test

sanimatic.com

Powered by