7.2 Recirculation System The recirculation system draws cleaning solution from the chamber sump and distributes it to the chamber’s rotary sprays It is self-contained within the system’s footprint • Recirculation system components − One (1) Pneumatic butterfly valve for system draining − One (1) 30" tri-clamp chemical injection port ◊ Tri-clamp cap contains three (3) 025" FNPT ports for chemical injection − One (1) Centrifugal supply pump ◊ 316Lss wetted materials with EPDM elastomers ◊ 3500 rpm, TEFC motor − One (1) Temperature transmitter with 30-230 °F range and 4-20 mA output − One (1) Pressure gauge with 0-100 psi range − One (1) Sanitary piping manifold
Table 5: Pump Data
Pump Rating
Chamber Model
HP
gpm 200 400
psi
P335 P365 P565
10
43
20
50 45
15
300
NOTE: • Pump rating data is based on Ampco pumps Ratings may change for other pump manufacturers
7.3 Heating System Steam is injected directly into the chamber sump to heat the recirculating cleaning solution The steam assembly contains the following components: • One (1) Steam sparger assembly − Duty: See Table 6: Direct Steam Injection Performance − Material: 316ss with welds color cleaned − Insulation: None − Design: Direct steam injection − Rating: Non-ASME − Connections: Tri-clamp (sump connection), MNPT (steam connection) • Steam supply piping manifold constructed of uninsulated SCH 40 304ss socket weld pipe and fittings − One (1) Pressure gauge with 0-100 psi range anti-siphon and manual block valve
− One (1) Steam strainer with manual blow-down valve − One (1) On/off ball valve with pneumatic actuator − One (1) Check valve
Table 6: Direct Steam Injection Performance
Approx. Heat-up Time 68 °F to 140 °F (min)
Chamber Model
P335 P365 P565
2
3 3
NOTE: • For direct steam injection, the SaniCab P requires a steam pressure of 50 psi or less Installations where the plant supplied steam is more than 50 psi, a pressure reducing valve (PRV) is required (by others)