7.4 CONTROL SYSTEM 7.4.1 Control Panel
• One (1) UL Listed enclosure, NEMA 4X, 304ss construction with painted carbon steel back plate • One (1) Allen-Bradley Bulletin 5069 CompactLogix 5380 with associated digital and analog outputs • One (1) Disconnect switch rated for 30 Amps (P335 model) or 60 Amps (P365 and P565 models)
• One (1) 24V DC, 5 Amp power supply • One (1) Ethernet switch (unmanaged) • One (1) Instrument air filter • One (1) Low air pressure alarm switch • One (1) Air pressure regulator with gauge 7.4.2 Operator Interface
The PanelView Plus 7 Operator Terminal is mounted on the side of the control panel facing the front of the system for easy operator access. • One (1) Allen-Bradley PanelView Plus 7 from Rockwell Automation - 7” color touchscreen, Operator Terminal • One (1) Illuminated emergency stop switch
• One (1) Illuminated reset button • One (1) 120V AC GFCI Receptacle • One (1) RJ45-F Ethernet Passthrough
PanelView Plus 7
8 EQUIPMENT OPERATION
8.1 SYSTEM OPERATING CONDITIONS
Chamber Model
Maximum System Operating Temperature (Rinse & Wash Phases)
P335 P365 P565
180 °F 165 °F 180 °F
8.2 LOADING AND UNLOADING OPERATION • Loading
ο Dirty parts are loaded onto the appropriate rack (racks sit atop a transfer cart) ο The transfer cart is pushed from the process area to the SaniCab P system ο The operator opens the SaniCab P door ο The transfer cart with rack is positioned in front of the SaniCab P doorway and is pushed into the rail assembly inside the washer for engagement and locking ο The transfer cart’s rack engagement lock is lifted, and the rack is pushed from the transfer cart into the chamber ο The operator disengages the empty transfer cart from the rail assembly, pulls the transfer cart away from the chamber, and closes the SaniCab P door ο The operator selects the appropriate cleaning cycle, also known as recipes, from the HMI operator terminal • Unloading ο The operator opens the SaniCab P door at the completion of the cleaning cycle (cleaning cycle completion is indicated on the HMI) ο An empty transfer cart is positioned in front of the SaniCab P door and is pushed into the rail assembly inside the washer for engagement and locking ο The process parts rack is pulled from the chamber onto the transfer cart ο The operator disengages the transfer cart from the rail assembly, pulls the transfer cart away from the chamber, and closes the door ο The transfer cart is pushed from the SaniCab P system to the process area ο Clean process parts are unloaded off the rack
11
Powered by FlippingBook