TANKO® SF_IOM_Rev0

Spate cleaner TANKO-SF

5.2.3 Installing the Device

NOTE Risk of dirt and foreign objects in the device!

Functional safety and reliability may be compromised.

 During installation, make sure and check that there is no dirt or foreign bodies in the device (e.g. small particles, sealing material).

Installation with Clipon Variant

Wire locking pin as delivered

Picture 5.2-3: Clipon Installation

NOTE Multiple utilization of the wire locking pin.

The material experiences fatigue and loses its rigidity when the wire locking pin is subjected to multiple bending. The nozzle carrier may come loose.

The device and the wire locking pin could fall into the container.

 The wire locking pin is to be replaced by a new wire locking pin after it has been bent (see section 7.5.1 Spare Parts ). NOTE Non-observance of the dimensions for the media connection (see Picture 5.2-2: Dimensions ). Problems with the fastening of the device to the downpipe could be the result.  The distance between the bore hole for the clip in the downpipe and the end of the downpipe may not exceed a maximum of 8 mm.

 The bore hole diameter for the clip in the downpipe is 3.2 mm.

1. Slide the axle (1) over the downpipe and rotate it until the clip bore holes in the downpipe match the clip boreholes in the axle (1). 2. Insert the wire locking pin (5) through the bore holes in the downpipe and axle (1) until it hits the stopper. 3. Bend the straight end of the wire locking pin (5) with the assembly/disassembly tool for the locking pin 2.4 mm by at least 45° (see Picture 5.2-3: Clipon Installation ).

4. Check whether the cage can rotate freely.

5 Installation

Translation of the original Operating / Installation Instructions 2016/09 Rev.1 27/63

Powered by