TANKO® SF_IOM_Rev0

Spate cleaner TANKO-SF

Installation with Weldon Variant

In order to be in compliance with the requirements hygiene, it is necessary to weld the welding version of the TANKO-SF to the end of a straight downpipe. This straight downpipe must be connected to the supply system for the medium in a way that can be dismantled. This must enable simple assembly and disassembly (e.g. by means of a hygienic clamp coupling) and must permit a visual inspection (through the downpipe) of the interior side of the downpipe and of the connection element. The welding must be carried out in accordance with the hygienic Standard. No bore hold is required in the downpipe for the welding version. The downpipe end is welded directly to the connection (axle 1).

1. Unfasten the nut (3) and unscrew it from the axle (1).

2. Keep the O-ring (4).

4. Remove the cleaning head (2) from the shaft (1).

5. Weld the axle (1) to the end of the downpipe as described above.

6. Slide the cage (2) with the semicircular outlet opening (Smiley) facing the connection over the axle (1) until it hits the stopper. 7. NOTE The O-ring must be positioned correctly in the O-ring groove. Screw the nut (3) with the O-ring (4) onto the axle (1) and tighten with torque 20 – 25 Nm (14.7 – 18.4 lbft).

8. Check whether the cage can rotate freely.

28/63 Translation of the original Operating / Installation Instructions 2016/09 Rev.1

5 Installation

Powered by