Maintenance Intervals and Methods
Shorten the maintenance intervals by 30% in the event of:
– Deviation from the preferred installation position of the device (see section 5.2.2 Installation Position),
– Vibrations that occur in the plant which are NOT caused by the device and CANNOT be prevented.
If the device is NOT operated for a longer period, we recommend that you check the device completely before re-commissioning to make sure that it is fully functional (see section 6.2 Functional Check / Trial Run ).
The specified times of the maintenance intervals are based on single-shift operation (8 hours per working day, 12 months per year) of the device and operation with
Cleaning agent:
Water
Media pressure:
2 bar (29 psi)
Media temperature:
+25 °C (+77 °F)
Interval:
h O
= operating hours of the device
Method:
V = visual inspection F = functional check M = measurement C = cleaning*
*The cleaning intervals are to be defined by the operating company in accordance with operating conditions.
Overview of Maintenance Points
A Axle (Media Connection [MC])
E
A
B Cage
C Nut
D O-ring
B
E Wire locking pin (only with Clipon)
D
C
Picture 7.4-1: Maintenance Points
42/63 Translation of the original Operating / Installation Instructions 2016/09 Rev.1
7 Maintenance
Powered by FlippingBook