TANKO® SF_IOM_Rev0

Spate cleaner TANKO-SF

Maintenance Intervals and Methods

Shorten the maintenance intervals by 30% in the event of:

– Deviation from the preferred installation position of the device (see section 5.2.2 Installation Position),

– Vibrations that occur in the plant which are NOT caused by the device and CANNOT be prevented.

If the device is NOT operated for a longer period, we recommend that you check the device completely before re-commissioning to make sure that it is fully functional (see section 6.2 Functional Check / Trial Run ).

The specified times of the maintenance intervals are based on single-shift operation (8 hours per working day, 12 months per year) of the device and operation with

Cleaning agent:

Water

Media pressure:

2 bar (29 psi)

Media temperature:

+25 °C (+77 °F)

Interval:

h O

= operating hours of the device

Method:

V = visual inspection F = functional check M = measurement C = cleaning*

*The cleaning intervals are to be defined by the operating company in accordance with operating conditions.

Overview of Maintenance Points

A Axle (Media Connection [MC])

E

A

B Cage

C Nut

D O-ring

B

E Wire locking pin (only with Clipon)

D

C

Picture 7.4-1: Maintenance Points

42/63 Translation of the original Operating / Installation Instructions 2016/09 Rev.1

7 Maintenance