TD-0005_Hygienic Spray Deflector - F&B_TD_Rev1.0

Cv Values

• Cv values provided for both airflow out of the tank (Venting Out) and for airflow into tank (Venting In) • V alues are valid for air at sub-critical flow velocities

Connection Size

Cv (Venting Out)

Cv (Venting In)

2.0" 3.0" 4.0"

53

60

102

223

188

212

Hygienic Spray Deflector Venting Out

Sub-Critical Flow when P 1 < 2 x P 2

(P 1 2 - P 2 2 ) (S.G. x T)

Q G =

962 x Cv

Hygienic Spray Deflector Venting In

Q G = Gas Flow in Standard Cubic Feet per Hour T = Absolute temperature in °R (°F + 460) P 1 = Upstream (Inlet) pressure in psia P 2 = Downstream (Outlet) pressure in psia psia = Absolute pressure. This is psig (gauge pressure) plus 14.7 (atmospheric pressure) S.G. = Specific Gravity of medium where air at 70 °F and 14.7 psia = 1.0