TANKO® JM_IOM_Rev1

Jet Cleaner TANKO-JM

recommended minimum dimensions for the installation opening and for installing the device in the container and removing it from the container in assembled condition. A “ stationary device ” can be installed in different ways depending on the properties of the container and the size and accessibility of the installation opening. – Before installation, the device is fastened to the media connection [MC] at the downpipe [DP] and inserted into the container from the outside via the installation opening. The process connection [PC] of the downpipe [DP] is then fastened to the container or

– the device is fastened to the media connection [MC] on an existing downpipe [DP].

WARNING Risk of the device falling accidentally!

The device may strike personnel when falling.

There is a risk of severe physical injuries.

 Hold the device firmly when installing/removing it.  There must be nobody beneath the device when installing/removing it.

NOTE Risk of dirt and foreign objects in the device!

Functional safety and reliability may be compromised.

 During installation, make sure and check that there is no dirt or foreign objects in the device (e.g. small particles, sealing material). NOTE No torque may be initiated into the device via the nozzles while the device is being installed/removed! Lever action can cause a torque to be transferred via the nozzle carrier to the bevel gear wheels. The threaded connections of the bevel gear wheels could become loose.  When setting the device down with the downpipe fastened in place, make sure that the nozzles ARE NOT under pressure due to the weight and length of the downpipe.  Clamp the downpipe in a vise so that the device can be fastened to or loosened from the downpipe.

Interface A

The supply line connection must be configured to be compatible with the media connection [MC] of the device. The supply line for the cleaning agent must be fastened permanently and leak-tight to the media connection [MC].

Threaded Connection

NOTE Risk of damage to the device during assembly!

The flats on the housing are NOT suitable for fastening and unfastening the device on the pipe for the media supply. The threaded connection between the housing and the connection cover may become damaged as a result of excessive tightening torque. Maintenance and cleaning may become more difficult or even impossible.