7. NOTE Housing (02) could fall down! The housing (02) can become damaged by the impact.  When screwing out the parts, take care to ensure that the housing (02) CAN NOT fall down (e.g. by holding it with one hand).  Undo the rotor shaft with star wheel (12) with the aid of the assembly/disassembly tool for rotors and screw it out of the shaft-axle connection (15).  Lift the housing (02) with the rotor shaft with star wheel (12) and the parts (03; 04; 13; 14) from the shaft-axle connection (15). 8. NOTE Incorrect clamping in the vise can cause threaded connections to become jammed and deformed unintentionally! The threaded connection cannot be screwed and may become damaged.  The jaws of the vise must not be clamped either too firmly or too close to the area of the threaded connection to be loosened.  Screw the connection cover (01) back into the housing (02) so that the housing (02) does not become dented while clamping.  Clamp the housing (02) together with the parts (03; 04; 13; 14) in the vise. The bevel gear wheel for housing (14) faces upwards. 9. Unfasten the bevel gear wheel for the housing (14) with a face wrench and unscrew it from the housing (02).

10. Remove sliding disks (03 and 04) and the bearing bush (13) from the housing (02).

11. Remove the housing (02) from the vise.

2) Disassembly - Cleaning Head Assembly Unit

1. Clamp the cleaning head on the nozzle carrier (18) in the vise.

2. Unfasten the nozzle (08) and unscrew it from the nozzle carrier (18).

3. Use a pair of pliers to pull the jet concentrator (09) from the nozzle (08).

4. Clamp the shaft-axle connection (15) in the vise.

5. Slide a square bar (10 x 10 mm) through the bores in the nozzle carrier (18) within the slot of the axle for nozzle carriers (16). 6. Use the square bar (10 x 10 mm) to loosen the axle for nozzle carriers (16) and screw it out of the from the shaft-axle connection (15). 7. NOTE The balls (06, 07) could become lost! The balls (06; 07) fall out and will NOT be intercepted!  Clamp the nozzle carrier (18) in the vise and use the face wrench to loosen the bevel gear wheel for nozzle carriers (17).  Remove the nozzle carrier (18) with the parts (06; 07; 16; 17) from the vise.  Unscrew the bevel gear wheel for nozzle carrier (17) out of the nozzle carrier (18) over a collecting receptacle and carefully catch the balls (06; 07), above and below the axle for nozzle carriers (16). The device is now completely disassembled. The individual parts can now be checked for soiling or damage and cleaned as necessary (e.g. in an ultrasound bath). Damaged parts and wear parts that exhibit signs of wear must be replaced.

62/90

Translation of the original Operating / Installation Instructions 2016/12

7 Maintenance

Powered by