TANKO® JM_IOM_Rev1

Jet Cleaner TANKO-JM

2) Disassembly - Cleaning Head Assembly Unit

1. Clamp the axle for nozzle carriers (13) on the flat surfaces into the vise.

2. Use a screwdriver or a screwdriver insert to screw locking screw (18) out of the axle for nozzle carriers (13).

3. Slide bevel gear wheel with nozzle carrier (14) from the axle for nozzle carriers (13).

4. Remove axle for nozzle carriers (13) from the vise.

5. Clamp the bevel gear wheel with nozzle carrier (14) in the vise.

6. Unfasten the nozzle (06) and unscrew it from the bevel gear wheel with the nozzle carrier (14).

7. Use a pair of pliers to pull the jet concentrator (07) from the nozzle (06).

8. Remove the bevel gear wheel with nozzle carrier (14) from the vise.

9. Lever the circlip (17) out of the internal groove on the bevel gear wheel with nozzle carrier (14) by applying the flat tip of a small screwdriver to the removal notch.

10. Press the collar bushing for nozzle carriers (04) out of the bevel gear wheel with nozzle carrier (14).

The device is now completely disassembled. The individual parts can now be checked for soiling or damage and cleaned as necessary (e.g. in an ultrasound bath). Damaged parts and wear parts that exhibit signs of wear must be replaced.

7.4.3.2 Removing the JM500 Device

The item numbers shown in brackets refer to the Figure 7.5-2: Internal construction of the JM500-G22.

1) Disassembly - Actuator Unit Assembly

1. NOTE Incorrect clamping in the vise can cause threaded connections to become jammed and deformed unintentionally! The threaded connection cannot be screwed and may become damaged.  The jaws of the vise must not be clamped either too firmly or too close to the area of the threaded connection to be loosened.  Clamp the device in the vise in such a way on the housing (02) that the threaded connection on the connection lid (01) does NOT become jammed. 2. Loosen the connection lid (01) and unscrew it from the housing (02).

3. Remove the inflow disk (11) together with the plug (10) from the housing (02).

4. If necessary, screw the plug (10) out of the inflow disk (11).

5. Loosen 3x threaded pins (19) on the shaft-axle connection (15) and screw them out.

6. Clamp the device in the vise on the flat surfaces of the shaft-axle connection (15).

7 Maintenance

Translation of the original Operating / Installation Instructions 2016/12

61/90

Powered by