TANKO® JM_IOM_Rev1

Jet Cleaner TANKO-JM

7.4.3.1 Removing the JM100 Device

The item numbers shown in brackets refer to the Figure 7.5-1: Internal construction of the JM100-G22.

1) Disassembly - Actuator Unit Assembly

1. NOTE Incorrect clamping in the vise can cause threaded connections to become jammed and deformed unintentionally! The threaded connection cannot be screwed and may become damaged.  The jaws of the vise must not be clamped either too firmly or too close to the area of the threaded connection to be loosened.  Clamp the device in the vise in such a way on the housing (02) that the threaded connection on the connection lid (01) does NOT become jammed.

2. Loosen the connection lid (01) and unscrew it from the housing (02).

3. Remove the inflow disk (09) from the housing (02).

4. If necessary, loosen the plug (08.1; 08.2) and screw if off the inflow disk (09) .

5. Clamp the device on the flat surfaces of the axle for nozzle carriers (13) in the vise.

6. NOTE Housing (02) could fall down! The housing (02) can become damaged by the impact.  When screwing out the parts, take care to ensure that the housing (02) CAN NOT fall down (e.g. by holding it with one hand).  Loosen the rotor star wheel (11) with the assembly/disassembly tool for rotor star wheel and unscrew it from the rotor shaft (10). Remark: The rotor shaft (10) can become detached at the same time.  Loosen the rotor shaft (10) with a WAF 28 socket wrench and screw it out of the axle for nozzle carriers (13).  Lift the housing (02) together with the rotor shaft (10) and the parts (03, 05, 12, 15, 16) from the axle for nozzle carriers (13).

7. Remove the sliding disk (05) from the rotor shaft (10)

8. Press the collar bushing for housing (03) out of the housing (02).

9. NOTE Incorrect clamping in the vise can cause threaded connections to become jammed and deformed unintentionally! The threaded connection cannot be screwed and may become damaged.  The jaws of the vise must not be clamped either too firmly or too close to the area of the threaded connection to be loosened.  Screw the connection cover (01) back into the housing (02) so that the housing (02) does not become dented while clamping.  Clamp the housing (02) with the parts (02, 12, 15, 16) in the vise. The bevel gear wheel (12) faces upwards. 10. Lever the round wire spring-lock washer (16) out of the groove and from the housing (02) with the flat tip of a small screwdriver.

11. Lift the bevel gear wheel for the housing (12) from the housing (02).

12. Secure dowel pin (15) against becoming lost.

60/90

Translation of the original Operating / Installation Instructions 2016/12

7 Maintenance