TANKO® JM_IOM_Rev1

Jet Cleaner TANKO-JM

9. Clamp the housing (03) in the vise.

10. Screw and tighten the plug (08.1; 08.2) in the inflow disk (09).

11. Place the inflow disk (09) with the even surface facing downwards into the housing (02).

12. Screw the connection cover (01) into the housing (02) and tighten it.

13. Remove the screwed parts from the vise.

The device is fully assembled and ready for installation (see section 5.2 Installation ) on the plant.

7.4.4.2 Assembling the JM500 Device

The item numbers shown in brackets refer to the Figure 7.5-2: Internal construction of the JM500-G22. The tightening torque values for the screw connections required for assembly are listed in the Table 7.5-4: JM500 tightening torque values.

1) Assembly - Cleaning Head

1. NOTE The balls (06, 07) could become lost! The balls (06; 07) fall out and will NOT be intercepted!  Use a collecting receptacle for positioning the balls (06; 07).  Insert a locating pin (e.g. plastic cap or similar) from the outside to the inside through the axle bore bevel gear wheel for nozzle carriers (17). 2. Carefully use a pair of tweezers to place the first layer of balls around the locating pin on the running surface. Depending on the version: – 22 stainless steel balls (06) alternating – 11 stainless steel balls (06) and 11 Nylon balls (07) 3. With the thread facing downwards, insert the axle for nozzle carriers (16) through the axle bore bevel gear wheel for nozzle carriers (17) while at the same time pulling the locating pin back out. 4. Position the bevel gear wheel for nozzle carrier (17) in such a way that the axle for nozzle carriers (16) can hang downward freely. 5. Carefully use a pair of tweezers to place the second Place bearing balls around the axle for nozzle carriers (16) on the running surface. Depending on the version: – 28 stainless steel balls (06) alternating – 14 stainless steel balls (06) and 14 Nylon balls (07) 6. Screw the bevel gear wheel for the nozzle carrier (17) into the nozzle carrier (18) and tighten it with a face wrench.

7. Check to see if the nozzle carrier (18) on the axle for nozzle carriers (16) is rotating freely!

8. Clamp the shaft-axle connection (15) in the vise.

9. Slide square bar (10 x 10 mm) through the nozzle bores of the nozzle carrier (18) into the slot of the axle for nozzle carriers (16). 10. Screw the axle for nozzle carriers (16) with the preassembled parts (06; 07; 16; 17; 18) into the shaft-axle connection (15) and tighten with the square bar (10 x 10 mm).

66/90

Translation of the original Operating / Installation Instructions 2016/12

7 Maintenance

Powered by