TANKO® S & TANKO® RB_IOM_Rev0

ATEX Spate Cleaner TANKO-EX-S and ATEX Spray Cleaner TANKO-EX-RB

2.5.2 Type Plate

The specifications only apply to devices with types indicated on the cover sheet of these instructions.

The marking is applied to the device according to the following illustration.

A) No. of designated body that audits the QA system in AWH B) Manufacturer C) Year of manufacture D) Type E) Labeling the ignition protection type F) Material G) Serial number (internal plant number) H) No. of the EC type test certificate

A

B

C

D

E

F

H

G

Figure 2.5-1: Type Plate Position

2.5.3 Labeling for Explosion Protection

The labeling of spate and spray cleaners in explosion-proof design is made by specifying the device group, category, ignition protection type and temperature class on the type plate. A CE and Ex mark confirms compliance of the device with European Directive 2014/34 / EU. NOTE ON EXPLOSION PROTECTION The ATEX spate cleaner type TANKO-EX-S and the ATEX spray cleaner Type TANKO-EX-RB devices are in device group II and are approved for the following application:

– Zone 0 (explosive gas atmosphere that exists permanently or over an extended period)

– Zone 20 (explosive dust atmosphere that exists permanently or over an extended period)

The use of devices in device group II, category 1G is enforced for Zone 0. The use of devices of at least device group II, category 2G is enforced for Zone 1. The use of devices of at least device group II, category 3G is enforced for Zone 2. The use of devices in device group II, category 1D is enforced for Zone 20. The use of devices of at least device group II, category 2D is enforced for Zone 21. The use of devices of at least device group II, category 3D is enforced for Zone 22.

The operator is responsible for division into zones.

15/79

2 Safety

Translation-Operating/Installation Instructions 2017/10

Powered by