TANKO® S & TANKO® RB_IOM_Rev0

ATEX Spate Cleaner TANKO-EX-S and ATEX Spray Cleaner TANKO-EX-RB

The type plate on the device also contains the information required for operation in a potentially explosive atmosphere according to the ATEX directive:

– Labeling the ignition protection type

– Number of the EC type test certificate

Labeling according to ATEX directive:

II 1 GD c T(X)

1) CE mark (labeling of compliance)

2) ID number of the designated body

3) Device labeling “ATEX”

4) Device group II

5) Device category 1

6) Potentially explosive “gas” and “dust” atmospheres

7) Protection type “Designed safety”

8) Temperature class T(X) (+10 °C – max. +180 °C)

(+50 °F – max. +356 °F)

The “ X ” symbol means that the safe use of the device depends on specific operating conditions specified in the operating instructions. The maximum surface temperature of the device (Zone 0 interior) is determined by the ambient temperature in the container to be cleaned and/or the temperature of the cleaning agent. This temperature can increase to max. +180 °C (+356 °F).

16/79

Translation-Operating/Installation Instructions 2017/10

2 Safety

Powered by