TANKO® S & TANKO® RB_IOM_Rev0

ATEX Spate Cleaner TANKO-EX-S and ATEX Spray Cleaner TANKO-EX-RB

Device type

Range: - Cleaning radius Operating temperature (permitted): – Cleaning agent

0.75 m (2.5 ft)

1.0 m (3.3 ft)

2.0 m (6.6 ft)

1.5 m (4.9 ft)

max. 180 °C (max. +356 °F)

Ambient temperature (permitted): – Inside the container

+10 °C – max. 180 °C (+50 °F – max. +356 °F)

Operating pressure: – Cleaning agent

< 1 – 7 bar (14.5 – 101.5 psi)

< 1 – 12 bar (14.5 - 174 psi)

< 1 – 10 bar (14.5 – 145 psi)

< 1 – 12 bar (14.5 - 174 psi)

< 1 – 7 bar (14.5 – 101.5 psi)

< 1 – 12 bar (14.5 - 174 psi)

< 1 – 7 bar (14.5 – 101.5 psi)

Optimum pressure: – Cleaning agent

approx. 3 bar (43.5 psi)

0 – 35 l/min

0 -120 l/min

0 -120 l/min

0 -240 l/min

0 -240 l/min

0 -680 l/min

0 -680 l/min

Volume flow rate:

Installation opening min.:

1), 2)

1)

2)

1)

2)

1)

2)

Media connection [MA]:

For the relevant technical data, please refer to the product pages of the current AWH “ Stainless steel cleaning equipment ” catalog.

43 – 69 mm (1.69 – 2.72 in)

60 – 86 mm (2.36 – 3.39 in)

93 -109 mm (3.66 – 4.29 in)

158 -181 mm (6.22 – 7.13 in)

Length [L]"

17 mm (0.67 in)

25 mm (0.98 in)

39 mm (1.54 in)

70 mm (2.76 in)

Head diameter [DK]"

26 – 47 g

81 – 132 g

248 – 323 g

1650 – 1780 g

Weight

90° down / 180° down / 180° up / 270° up / 360°

Spray pattern:

180° down / 180° up / 270° up / 360°

Rotation speed: – with water

1000 – 3000 U/min (depending on the device and pressure):

Installation Position:

Vertically suspended Others possible, although with shorter service life of the plain bearings

see Table 3.3-3 ; Table 3.3-4 and Appendix 2: Corrosion resistance of the materials

Materials:

Dependent on the properties of the container! The noise pressure level can exceed the maximum permissible Exposition value of L EX,8h = 85 dB (A).

Noise pressure level - Outside the container

Table 3.3-1: Operating parameters of the device TANKO-EX-S

1) The installation opening of the threaded and welded connection variants must be 2 mm larger than the head exterior diameter of the device. 2) The installation opening of the clip-on connection variant must be 2 mm larger than the installed connection element.

20/79

Translation-Operating/Installation Instructions 2017/10

3 Construction and Function

Powered by