TANKO® S & TANKO® RB_IOM_Rev0

ATEX Spate Cleaner TANKO-EX-S and ATEX Spray Cleaner TANKO-EX-RB

Device type

Range: - Cleaning radius

0.75 m (2.5 ft)

1.25 m (4.1 ft)

1.5 m (4.9 ft)

2.5 m (8.2 ft)

Operating temperature (permitted): – Cleaning agent Ambient temperature (permitted): – Inside the container

max. 180 °C (max. +356 °F)

+10 °C – max. 180 °C (+50 °F – max. +356 °F)

Operating pressure: – Cleaning agent

< 1 – 5 bar (14.5 - 72.5 psi)

< 1 – 5 bar (14.5 - 72.5 psi)

< 1 – 7 bar (14.5 - 72.5 psi)

< 1 – 5 bar (14.5 - 72.5 psi)

< 1 – 7 bar (14.5 – 101.5 psi)

< 1 – 5 bar (14.5 - 72.5 psi)

Optimum pressure: – Cleaning agent

approx. 3 bar (43.5 psi)

Volume flow rate:

0 – 60 l/min 0 – 200 l/min

0 – 400 l/min

0 – 590 l/min

Installation opening min.:

1), 2)

1), 2)

1)

2)

1)

2)

For the relevant technical data, please refer to the product pages of the current AWH “ Stainless steel cleaning equipment ” catalog.

Media connection [MA]:

80 – 102 mm (3.15 – 4.02 in) 40 mm (1.57 in)

70 – 90 mm (2.76 – 3.54 in)

120 – 140 mm (4.72 – 5.51 in)

160 – 185 mm (6.30 – 7.28 in)

Length [L]

30 mm (1.18 in)

64 mm (2.52 in)

90 mm (3.53 in)

Head diameter [DK]

160 g

190 g

370 g

470 – 690 g

Weight

180° down / 180° up / 360°

Spray pattern:

180° down / 180° up / 270° up / 360°

Speed of rotation: – with water

1000 – 3000 U/min (depending on the device and pressure):

Vertically suspended Others possible, although with shorter service life of the plain bearings

Installation Position:

see Table 3.3-3; Table 3.3-4 and Appendix 2: Corrosion resistance of the materials

Materials:

Dependent on the properties of the container! The noise pressure level can exceed the maximum permissible Exposition value of L EX,8h = 85 dB (A).

Noise pressure level - Outside the container

Table 3.3-2: Operating parameters of the device TANKO-EX-RB

1) The installation opening of the threaded and welded connection variants must be 2 mm larger than the head exterior diameter of the device. 2) The installation opening of the clip-on connection variant must be 2 mm larger than the installed connection element.

21/79

3 Construction and Function

Translation-Operating/Installation Instructions 2017/10

Powered by