ATEX Spate Cleaner TANKO-EX-S and ATEX Spray Cleaner TANKO-EX-RB

5.2.3 Installing the Device

WARNING Risk of the device falling accidentally!

The device may strike personnel when falling.

There is a risk of severe physical injury.

 Hold the device firmly when installing/removing it.

 There must be nobody beneath the device when installing/removing it.

NOTE Risk of dirt and foreign objects in the device!

Functional safety and reliability may be compromised.

 During assembly, make sure and check that there is no dirt or foreign objects in the device (e.g. small particles, sealing material).

Installation welded connection

NOTE The temperature in the ball bearings area must not exceed 90 °C during welding!

The result is distortion of the housing and disruption of the rotational behavior.

 Ensure suitable cooling measures during welding.

 Request special versions (e.g. extended welding ends) from AWH.

1 Ball-bearings

(similar to picture)

1

Figure 5.2-2: Weld-on design

1. Cleaning the parts to be welded.

2 . NOTE Welding distortion can be avoided by selecting suitable welding parameters.

Aligning and welding the TANKO-S with the downpipe (on-site).

The operating company is responsible for the selection of the correct welding filler and for the correct execution of the welding connection.

36/79

Translation-Operating/Installation Instructions 2017/10

5 Installation