TANKO® S & TANKO® RB_IOM_Rev0

ATEX Spate Cleaner TANKO-EX-S and ATEX Spray Cleaner TANKO-EX-RB

Base Material

Suitable Filler Material

1.4435

1.4430, 1.4440

2.4602

2.4607

Table 5.2-1: Recommended Filler Materials

3. Welding

– Before welding, connect the forming gas.

– Before welding, affix 3 to 4 tack weld-ons.

4. Welding Post-Treatment

– In the interior area, an acid cleaning treatment is recommended after the welding.

– The surface of accessible points can be improved by grinding.

– The exterior can be treated afterwards by staining, brushing, grinding and polishing.

– After welding, thoroughly rinse the downpipe with the device to remove residues from welding and after-treatment.

5. Install downpipe with device in the container.

Installation threaded connection

1 Do NOT place the strap wrench/belt pipe wrench in the ball bearings area

1

Figure 5.2-3: Installation threaded connection

1. Push the device with the interior thread onto the pipe for the media supply.

NOTE There is a risk of damage to the thread if the tightening torque applied to the threaded device connection and the pipe is excessive!  The tightening torque value between the threaded device connection and the pipe depends on the material of the pipe for the media supply.

37/79

5 Installation

Translation-Operating/Installation Instructions 2017/10

Powered by