TANKO® S & TANKO® RB_IOM_Rev0

ATEX Spate Cleaner TANKO-EX-S and ATEX Spray Cleaner TANKO-EX-RB

Interval

Inspection and Maintenance Work

Initial inspection

Follow-up check

Check spray openings for contaminations, wear and damage.

A

200 h B

200 h B

S/R/A

 Clean in the event of contaminations.  Replace device in the event of wear or damage. Check functioning (rotatability) of actuator for contaminations, wear and damage.  Clean in the event of contaminations.  Replace device in the event of wear or damage. Check tightness of thread and check the functional safety of the thread lock.

B

200 h B

50 h B

R/S/F/A

C

200 h B

200 h B

S/F

Restore safety.

Check clip-on connection for contaminations, wear and damage.

 Replace device in the event of wear or damage to the connection.  Replace wire locking pin with original part.

D

200 h B

50 h B

S/A

Table 7.4-1: Inspection and Maintenance Work

NOTE Multiple utilization of the wire locking pin.

The material experiences fatigue and loses its rigidity when the wire locking pin is subjected to multiple bending. The wire locking pin may come loose.

The device and the wire locking pin could fall into the container.

 The wire locking pin is to be replaced by a new wire locking pin after it has been bent (see section 5.2.3 Installing the Device , “Installation Clip - on Connection” ).

58/79

Translation-Operating/Installation Instructions 2017/10

7 Maintenance

Powered by