DM-0005_Basket Strainer IOM_Rev3.0

Troubleshooting Table 3: Troubleshooting Problems

Solutions

1. Lubricate the o-ring. 2. Damaged or bent element handle (replace).

3. Damaged element (replace). 4. Damaged housing (replace).

Element won’t fit into housing.

1. If the debris is smaller than the perforation size, then a new element insert with smaller openings will be required. 2. A different straining element (perforated, wedgewire) may be required. 3. If present, the filter bag may be damaged (replace). 4. The element may be damaged (replace). 5. The element o-ring may be damaged or missing (replace). 1. Strainer element size may be too small (use a larger element size). 2. The strainer is not cleaned out adequately during cleaning steps. 3. A dual strainer assembly may be required to switch between strainers and continue running while one strainer is being used (contact Sani-Matic for more information). 1. Ensure that all bolts are hand-tightened. If leakage is still occurring replace the cover o-ring. 2. Check the system temperature and pressure to ensure the pressure does not exceed the pressure ratings.

Particles are passing by the strainer.

Strainer is plugging frequently.

Leakage occurring at cover.