DM-0006_Magnetic Trap Strainer IOM_Rev2.0

Step 9 Ensure there is a tight fit where the Magnetic Trap Strainer Element Frame, Gasket, and Angle-Line Strainer body meet.

Place 4" tri-clamp around the gasket, cap, and strainer body.

Fit the 4" tri-clamp to ensure complete closure. Move the threaded wing nut into place and tighten to 25 in. lb. of torque.

See the full Angle-Line Strainer IOM document (DM-0003) for final process installation instructions.

DM-0006_Magnetic Trap Strainer IOM_Rev2.0