Jet Cleaner TANKO-MX
Interface B The connection to the container must be designed to that it is compatible with the process connection [PC] for the downpipe [DP]. The process connection [PC] has to be fastened permanently and leak-tight to the connection on the container (e.g. screwed or clamped) and secured to prevent it from coming loose. WARNING NON-screwable process connections [PC], e.g. disconnectable connections with a clamp or catch design, may come loose unintentionally. There is a risk of fluids getting in or spraying out (carryover of zones). Process connections [PC] with a clamp or catch design must: – be self-locking (e.g. mechanical locking with safety lock) or – be provided with an additional securing mechanism to prevent them from coming loose accidentally.
The operating company is solely responsible for fastening the device to the container.
Interface C NOTE Excessively small installation opening for the container or components (e.g. agitators) in the container! Nozzles collide during installation. Damage to the device. The nozzle carrier may come loose. The nozzles must NOT collide! 1. Check the following before inserting the device into the container: – The minimum dimension for the installation opening (see section 3.3 Technical Data ), – Presence of interfering contours on surrounding components in the container and – That the nozzle carrier with nozzles is firmly in place on the cleaning head. 2. Insert the device into the container through the installation opening with the utmost care. NOTE “ Installation Opening – Stationary Device ” DO NOT turn the nozzle carrier with nozzles by hand. Fasten the cleaning head/device inside the container. – Provided that proper installation and assembly/removal of the cleaning head/device inside the container is assured and – the diameter of the installation opening on the container is at least 5 mm greater than the outer diameter of the downpipe [DP]. NOTE “ Installation opening – mobile device ” Smaller installation openings on the container “ for mobile use ” of the device, as specified in section 3.3 Technical Data , are not permitted: If the cleaning head fits through the installation opening with the nozzles in any position during installation and removal of the device (e.g. by using shorter nozzles) and a safety clearance of at least 5 mm all around the device between the device and the installation opening is ensured.
32 / 86
Translation of the original operating/installation instructions 2016/03
5 Installation
Powered by FlippingBook