Jet Cleaner TANKO-MX
7.4.3.1 Removing the MX125 Device
The item numbers shown in brackets refer to the Figure 7.5-1: Internal construction of the MX125.
On the cleaning head, there is a “ bore for self-cleaning ” of the device on the face of the nozzle carrier. This bore is also used for orientation when disassembly/assembly of the devices. The position of the “ bore for self-cleaning ” is denoted by the symbol in the illustrations. 1) Disassembly - Cleaning Head Assembly Unit 1. Fasten the device in the vise with the nozzle carrier (27) facing upwards, horizontally on the housing (02) and the shaft-axle connection (24). 2. Unfasten the nozzle (12) directly at the “ bore for self-cleaning ” with an open-end wrench or pliers wrench and unscrew the jet concentrator (13). 3. NOTE The threaded pin (34) may fall into the device when being unscrewed! Insert a hexagon socket wrench, size 2.5 mm, through the threaded hole on the face of the nozzle carrier (27) and into the threaded pin (34). Unfasten the threaded pin (34) and carefully unscrew it from the nozzle carrier (27).
4. Unfasten the nozzle carrier (27), e.g. using a belt wrench, and unscrew it from the driver shaft (25). 5. Remove the collar bushing (07) from the nozzle carrier (27).
54 / 86
Translation of the original operating/installation instructions 2016/03
7 Maintenance