TANKO® MX_IOM_Rev0

Jet Cleaner TANKO-MX

NOTE Left-hand thread of the connection! Turning the incorrect direction can damage the threaded connection.

4.

 Make sure that the threaded connection is turned in the correct direction “ LH ” (left-hand).  Screw the actuator unit assembly with the shaft-axle connection (22) into the dome of the shaft-axle connection (24).  Tighten the shaft of the spur gear (22) using the flats (WAF 14) with an open-end wrench.

5. Screw the threaded pin (34) into the dome of the shaft-axle connection (24) and tighten it with a hexagon socket wrench, size 2.5 mm. 6. Hold the screwed parts firmly with one hand and unfasten the vise. 7. Fasten the screwed parts again so that the housing (02) is in a horizontal position between the jaws and the thread for the bearing plate (28) faces upwards. 8. Press the bushing (09) into the dome of the shaft-axle connection (24).

9. Push the bevel gear wheel for the nozzle carrier (26) onto the driver shaft (25) with cylindrical pin (35). 10. Insert the spiral circlip (31) into the external groove on the driver shaft (25) in a spiral pattern and allow it to engage in place.

7 Maintenance

Translation of the original operating/installation instructions 2016/03

69 / 86

Powered by