11.1.1 Rack – Low Load Density (Budgetary) • Typical design may include: − Up to 50 parts − Up to 5 active sprays − Up to 5 active part connections 11.1.2 Rack – Medium Load Density (Budgetary) • Typical design may include: − 50-100 parts − Up to 10 active sprays − Up to 10 active part connections 11.1.3 Rack – High Load Density (Budgetary) • Typical design may include: − 100-150 parts − Up to 15 active sprays − Up to 15 active part connections

Parts

Active Part Connection (Hoses)

11.1.1

Active Coupler

11.1.4 Riboflavin Test – Rack This accessory provides a customer witnessed spray coverage testing using riboflavin for each rack Sani-Matic follows internal procedures that are developed using the ASME BPE Nonmandatory Appendix for Spray Device Coverage Testing A test report (SMI-LOG-004) is provided, documenting the system flow parameters as well as the rack part loading

11.1.2

Active Spray

11.1.3

NOTE: • This item is for riboflavin testing at Sani-Matic facilities The PharmaCab SP system, fabricated rack, and applicable customer parts must all be at Sani-Matic for execution • On-site riboflavin testing can be performed by Sani-Matic field service technicians; contact Sani-Matic for details

11.1.5 Passivation – Rack Sani-Matic will provide passivation of all rack surfaces A certificate of passivation is provided upon completion 11.1.6 Borescope Inspection Video – Rack Hygienic welds on the rack’s process piping are borescope inspected A DVD video record is provided

Riboflavin test

NOTE: • This item is only applicable to racks with active coupler connections and process piping within the rack

Borescope inspection view

sanimatic.com 21