4. Utility Requirements
The following are the minimum required utilities for the proper operation of the equipment If these utilities are not available, an Alternative Design Request may be required
Table 1: Utility Requirements
Water - Supply
Drain
Instrument Air
Electrical
Chemical
Chamber Model
Working Volume (Gal)
Connection Size / Type (Chamber)
Connection Size / Type (Pump Casing)
Disconnect Size @ 460V AC (amps)
Connection Size / Type
Flow Rate (gpm)
Connection Size / Type
Volume (cfm)
Connection Size / Type
SP333 SP443 SP444
10" TC 10" TC 10" TC
22 25 25
15" TC 15" TC 15" TC
05" TC 05" TC 05" TC
≤ 40 ≤ 40 ≤ 40
05" FNPT 05" FNPT 05" FNPT
20 20 20
100 100 100
05" TC 05" TC 05" TC
NOTE: • Drain temperature is variable based on the cycle • Water Supply
− Total water volume required is dependent on cycle parameters − Varying water supply temperatures can be accommodated
• Two (2) chemical ports located in the chamber sump sidewall are provided for chemical addition If backflow prevention is required, it is provided by others See Section 10.10 Chemical Addition for options to add local chemical pump and container assemblies • Electrical service is 3PH / 60 Hz
sanimatic.com 7
TD-0002.4