CLEAN-OUT-OF-PLACE (COP) PARTS WASHER
10.4 JET MANIFOLDS The selection of adding End Jet Manifolds and/or a Hose Cleaning Manifold to the standard side jets adds additional cleaning actions as described below. Addition of the options adds the required manual butterfly valves to direct wash solutions to either the side jet manifolds, end jet manifolds, or hose cleaning manifold. Systems are sized to operate only one zone at a time and should not be run simultaneously. The standard side jet manifold is included when selecting either or both of these options.
• End Jet Manifolds create agitation lengthwise within the tank and are best for washing piping, hoses, and other long hollow items.
• The Hose Cleaning Manifold provides four (4) 1.5” tri-clamp connections (UW model tanks) or four (4) 2.0” tri-clamp connections (RW, PW, TW model tanks) internal to the tank, submerged in the fluid. Hoses and/or tubing can be attached to these connections providing flow of wash solutions through their interior.
NOTE: • The End Jet Manifolds option adds approximately 3” in length to the system dimension. 10.5 HEATING The direct steam injection heating system can be removed to provide No Heating Method or can be replaced with an Electric Heater to Maintain Temperature . • The Electric Heater to Maintain Temperature is sized to maintain temperature only (up to 170 °F) and is dependent on the system being filled with water already at this temperature. This does not include heat loss due to parts loading or room environment conditions.
TABLE 5: ELECTRIC HEATER DATA
Electric Heater Sizing kW
Tank Series and Length
Amp Draw (460V AC)
UW04 UW06 UW08 UW10 UW12 RW04 RW06 RW08 RW10 RW12 PW04 PW06 PW08 PW10 PW12 TW04 TW06 TW08 TW10 TW12
9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0
12 12 12 12 12 12 12 12 16 16 12 12 16 16 16 12 12 16 16 16
ο See Table 5 (right) for kW & amperage ratings ο Temperature control with an integral thermostat ο 316Lss wetted materials
NOTE: • It is strongly recommended when adding the Electric Heater to Maintain Temperature option to add the Disconnect with Start / Stop Buttons and Electric Heater Controller option, which adds the proper heater to pump safety interlocks. Without the controls package selected, it is the responsibility of the end-user to install the proper interlocks – failing to install and test an interlocking method between the pump and the heating element could lead to serious safety hazards and voids any warranty.
12.0 12.0
9.0 9.0
12.0 12.0 12.0
9.0 9.0
12.0 12.0 12.0
12
CLEAN-OUT-OF-PLACE (COP) PARTS WASHER TECHNICAL DATASHEET
Powered by FlippingBook