TD-0001_COP Parts Washers_Technical Datasheet_Rev6.0

CLEAN-OUT-OF-PLACE (COP) PARTS WASHER

The minimum required utilities for the proper operation of the equipment are listed in Table 1 (below). If these utilities are not available, an Alternative Design Request may be required. 4 UTILITY REQUIREMENTS

TABLE 1: UTILITY REQUIREMENTS

Potable Water

Drain

Steam Supply

Electrical

Tank Series and Length

Approximate Time (min) for Full Tank Heat Up (55 °F to 140 °F)

Tank Fill (gallons)

Connection Size / Type

Load @ 50 psi (lbs/hr)

Connection Size / Type

Amps @ 230V AC

Amps @ 460V AC

UW04 UW06 UW08 UW10 UW12 RW04 RW06 RW08 RW10 RW12 PW04 PW06 PW08 PW10 PW12 TW04 TW06 TW08 TW10 TW12

62 91

2.0" TC 2.0" TC 2.5" TC 2.5" TC 2.5" TC 2.5" TC 2.5" TC 2.5" TC 3.0" TC 3.0" TC 2.5" TC 2.5" TC 3.0" TC 3.0" TC 3.0" TC 2.5" TC 2.5" TC 3.0" TC 3.0" TC 3.0" TC

377 377 742 742 742 377 742 742

12 12

0.50" FNPT 0.50" FNPT 0.75" FNPT 0.75" FNPT 0.75" FNPT 0.50" FNPT 0.75" FNPT 0.75" FNPT 1.00" FNPT 1.00" FNPT 0.75" FNPT 0.75" FNPT 1.00" FNPT 1.00" FNPT 1.00" FNPT 0.75" FNPT 0.75" FNPT 1.00" FNPT 1.00" FNPT 1.00" FNPT

7.0 7.0

3.5 3.5 6.0 6.0 9.0 6.0 6.0 9.0

120 149 178

8

12.0 12.0 18.0 12.0 12.0 18.0 36.0 36.0 12.0 18.0 36.0 36.0 36.0 12.0 18.0 36.0 36.0 36.0

10 10 12

95

140 185 230 275 138 203 267 332 397 132 195 257 319 382

9

12

1,272 1,272

9

18.0 18.0

11

742 742

9

6.0 9.0

13 10 13 15

1,272 1,272 1,272

18.0 18.0 18.0

742 742

9

6.0 9.0

13 10 12 15

1,272 1,272 1,272

18.0 18.0 18.0

NOTE: • All pumps are 230/460V AC dual rated. See Section 10.7 (Table 6) for disconnect size when selecting a controls package. • Drain temperature is variable based on COP cycle. • Steam Supply requirement is based on selection of the standard in-tank steam sparger. • Chemical requirement is dependent on cleaning process.