TACTaFlow™ Standardized, pre-engineered CIP systems ready to clean your process.
TACTaFlow™ S45
TACTaFlow™ CIP systems are cGMP and ASME BPE compliant and pre-engineered, ready to be dropped into your next specification package with available P&ID, 2D, and 3D design layouts. Make CIP system specification easy with the TACTaFlow from Sani-Matic — with options for mobile, 1 tank, and 2 tank systems with a wide array of options.
sanimatic.com
Simplify your CIP specification process with Sani-Matic's TACTaFlow for cleaning process equipment.
Industry Standard Compliance • FDA Current Good Manufacturing Practices (cGMP), CFR Title 21, Part 820 • Underwriters Laboratory (UL): Controls, Standard 508
Advantages • Wide operating range allows design to be used for many applications. • Immediate access to detailed technical specifications allows for reduced effort to generate data sheets and bid specifications. • Wide array of detailed options selections available minimizing effort required to generate specifications as well as reducing the likelihood of change orders. • Custom system automation options. From custom HMI screens to communication with process equipment, our team knows how to make the system work for you.
• ANSI/ISA-88 (S88) Batch Control • Authorized to Provide Canadian Registration Numbers (CRN) • ASME BPE Standards
System Automation Sani-Matic has designed, manufactured and supported thousands of CIP control systems with its in-house programmers and UL authorized panel shop. Advantages of Sani-Matic Controls • Experts. The Sani-Matic programming and automation team specializes in cleaning applications and provides proven expertise within the industry. • Automation Ease & Flexibility. Easy-to-understand Recipe Editor provides access to setpoints. Defined alarms reduce troubleshooting time. • Time, Water & Chemical Savings. Recipe optimization shortens cycle time and minimizes water and chemical use.
SaniTrend ® Cloud Reporting Software
Add SaniTrend ® Cloud Cleaning Reports (CR) software to your equipment to efficiently and automatically record and store critical data (e.g., temperature, conductivity). SaniTrend ® Cloud CR Insights+ records all critical data in easy-to-interpret cleaning records and additional insights like event logs, Overall Equipment Effectiveness (OEE) scoring, Preventive Maintenance (PM) Tracking, and more. The Insights+ edition also logs a full HMI Audit Trail and is 21 CFR Part 11 compliant for electronic records and signatures. Learn more at our website at sanimatic.com/sanitrendcloud/
sanimatic.com
S60
D60
S45
Model Overview
TACTaFlow S60
TACTaFlow D60
TACTaFlow S45 1 Tank CIP – Mobile
Design
1 Tank CIP
2 Tank CIP
Tank Working Volume CIP Flow & Pressure Application Size (lines) Application Size (vessels)
100 gal.
100 gal.
50 gal.
14-60 gpm @ 80 psig
14-60 gpm @ 80 psig
12-45 gpm @ 50 psig
Up to 2"
Up to 2"
Up to 2"
Up to 6' diameter
Up to 6' diameter
Up to 4.5' diameter
100 gal. / 20 °C to 65 °C / 10 minutes Allen Bradley CompactLogix PLC with PanelView +7
100 gal. / 20 °C to 65 °C / 10 minutes Allen Bradley CompactLogix PLC with PanelView +7
50 gal. / 20 °C to 65 °C / 22 minutes
Heating Capacity
Allen Bradley CompactLogix PLC with PanelView +7
Controls
Features
Standard Features • S upply tank – 316Lss / BPE SF2 designed for +14.5 psig/-14.7 psig (non-code)
• F rame – 304ss / 32 Ra welds color cleaned • H ygienic Piping – 316Lss / BPE SF2 • S team & Condensate heating system (S60 / D60) ; Electric heating system (S45) • Return flow switch • Chemical injection system • UL, NEMA 4X Control Panel & Components • System Programming
• C entrifugal supply pump w/ VFD – Fristam FPX • Pneumatic diaphragm valves – ITT Pure-Flo • C hemical and final rinse conductivity sensors • R adar tank level detection • S upply and return temperature sensors • C onduit – SCH40 PVC Coated Galvanized Steel Optional Features
• R iboflavin Test • 10" PanelView • Mass Coriolis Flowmeter • Pressure Transmitter • Tank Vent Filter(s) • ASME Pressure Rated Tank(s) • Air Blow • Sample Valve
• Electropolish (BPE SF4) • Piping Insulation • CIP Supply Routing Valve(s) • Drain Cooling or Routing Valves • Drain Pump • Sanitary Flex Hoses • Heating System Alternatives • SIP Function (S45 Only)
System Dimensions & Weights S60
D60
S45
Overall Size
74"L x 54"W x 90"H
112"L x 54"W x 90"H
90"L x 40"W x 85"H
Weight - Empty
1,850 lbs 2,700 lbs
2,300 lbs 4,000 lbs
1,750 lbs 2,300 lbs
Weight - Full
NOTE: System dimensions & weights may vary based on selected options.
BPB-0008.1
Pharma Multi-Tank TACTaFlow D60 Schematic
TACTaFlow S45 / S60 Schematic
Pharma 1-Tank
CE
FE
CE
FE
CIP Return
CIP Return
TE
TE
PW
CIP Supply
WFI
CIP Supply
Drain
WFI
PW
Drain
Steam
Wash/Rinse
Steam
Wash Solution
Rinse
Air
Air
LE
LE
LE
CE PE
FE
TE
CE PE
FE
TE
Supply Pump
Supply Pump
Chemical Supply
Chemical Supply
Drain
Drain
Condensate Return
Condensate Return
Drain
Drain
NOTE: Illustrative P&ID shown above. S45 uses electric heat as a standard. Design may vary based on selected options.
Operating Requirements
U TACTaFlow S60 / D60 ow 4 Description
Requirement
Connection
Water #1 – Purified Water
20 gpm @ ≤ 40 psi, 20 °C - 80 °C 20 gpm @ ≤ 40 psi, 20 °C - 80 °C
1.5" TC 1.5" TC 2.0" TC
Water #2 – WFI
Drain
≤ 60 gpm @ 20 °C - 80 °C
Instrument Air Steam Supply
10 cfm @ 90 psig
0.5" FNPT 1.0" Flange
450 lbs/hr @ 50 psig
Condensate Return
450 lbs/hr
1.0" Flange
30 Amp @ 460V AC, 3PH, 60 Hz (100A with Electric Heater option)
Electrical Supply
-
CIP Return (CIPR) (Optional)
10-60 gpm @ 30 psig
2.0" TC
U TACTaFlow S45w 45 Description
Requirement
Connection
Water #1 – Purified Water
20 gpm @ 20 psi, 20 °C - 80 °C 20 gpm @ 20 psi, 20 °C - 80 °C
1.0" TC 1.0" TC 2.0" TC
Water #2 – WFI
Drain
≤ 45 gpm @ 20 °C - 80 °C
Instrument Air
10 cfm @ 90 psig
0.5" FNPT
100 Amp @ 460V AC, 3PH, 60 Hz (30A with Steam Heat option)
Electrical Supply
--
NOTE: Operating requirements may vary based on selected options.
Documentation
Standard • Operation and maintenance manuals • Recommended spare parts (RSP) list • Mechanical Bill of Materials (BOM) • Instrumentation calibration procedures • Material Test Reports (MTRs) • W eld maps and weld logs (including qualification and inspection records) • Inspection test results, reports and certificates • Component vendor documentation • As-built General Assembly (GA) drawings • As-built Process and Instrumentation Diagrams (P&ID) • As-built electrical drawings • PLC & HMI code, I/O List
Optional • Functional Specifications (FS) • Configuration Specification (CS) • Factory Acceptance Test (FAT) • Site Acceptance Test (SAT) • Installation and Operation Qualification (IQ/OQ) • Traceability matrix
• Instrument data sheets • Passivation certificate
• Borescope Inspection Video • Hydrostatic test certificate • Riboflavin spray coverage test • Seismic zone anchorage calculations
sanimatic.com
BPB-0008.1
Cleaning Confidence. Repeatable results you can count on every time you clean your process parts and equipment. That’s Cleaning Confidence from Sani-Matic.
sanimatic.com
Sani-Matic, Inc.
(p)800-356-3300 (f)608-222-5348
Page 1 Page 2 Page 3 Page 4 Page 5Powered by FlippingBook