TACTAFLOW™ Standardized, Pre-Engineered CIP Systems For High Purity Applications.
TACTAFLOW™ S45
TACTaFlow™ CIP systems are cGMP and ASME BPE compliant and pre-engineered, ready to be dropped into your next specification package with available P&ID, 2D, and 3D design layouts. Make CIP system specifications easy with the TACTaFlow from Sani-Matic — with options for mobile, 1 tank, or 2 tank systems with a wide array of options.
Simplify your CIP specification process with Sani-Matic’s TACTaFlow™ for cleaning process equipment.
TACTaFlow P&ID
ADVANTAGES
Wide operating range allows design to be used for many applications.
Wide array of detailed option selections available minimizing effort required to generate specifications as well as reducing the likelihood of change orders. Make CIP System Specification Easy. Industry proven, ASME BPE compliant designs that are ready to drop into your high purity process.
Immediate access to detailed technical specifications allows for reduced effort to generate data sheets and bid specifications.
• FDA Current Good Manufacturing Practices (cGMP), CFR Title 21, Part 820 • Underwriters Laboratory (UL): Controls, Standard 508 • Authorized to Provide Canadian Registration Numbers (CRN) • ASME BPE Standards • 21 CFR Part 11 (for certain Data & Analytics Products) INDUSTRY STANDARD COMPLIANCE
CLEAN-IN-PLACE SYSTEMS
SYSTEM AUTOMATION Sani-Matic has designed, manufactured and supported thousands of CIP control systems with its in-house programmers and UL authorized panel shop.
ADVANTAGES OF SANI-MATIC AUTOMATION
Experts. The Sani-Matic programming and automation team specializes in cleaning applications and provides proven expertise and customized strategies. Automation Ease & Flexibility. Easy-to-understand Recipe Editor provides access to setpoints. Defined alarms reduce troubleshooting time. Custom System Automation. From custom HMI screens to communication with process equipment, our team knows how to make the system work for you.
SANITREND® CLOUD REPORTING SOFTWARE
Add SaniTrend ® Cloud Cleaning Reports (CR) software to your equipment to efficiently and automatically record and store critical data (e.g., temperature, conductivity). SaniTrend ® Cloud CR Insights+ records all critical data in easy- to-interpret cleaning records and additional insights like event logs, Overall Equipment Effectiveness (OEE) scoring, Preventive Maintenance (PM) Tracking, and more.
The Insights+ edition also logs a full HMI Audit Trail and is 21 CFR Part 11 compliant for electronic records and signatures.
Learn more at our website: sanimatic.com/sanitrendcloud/
3
S60
D60
S45
D60
Pharma Multi-Tank
Schematic Pharma 1-Tank
Schematic
CE
FE
CE
FE
CIP Return
CIP Return
TE
TE
PW
CIP Supply
WFI
CIP Supply
Drain
WFI
PW
Drain
Steam
Steam
Wash/Rinse
Wash Solution
Rinse
Air
Air
LE
LE
LE
CE PE
FE
TE
CE PE
FE
TE
Supply Pump
Supply Pump
Chemical Supply
Chemical Supply
Drain
Drain
Condensate Return
Condensate Return
Drain
Drain
NOTE: Illustrative P&ID shown above. S45 uses electric heat as a standard. Design may vary based on selected options.
MODEL OVERVIEW
TACTaFlow S45
TACTaFlow S60
TACTaFlow D60
Design
1 Tank CIP – Mobile
1 Tank CIP
2 Tank CIP
Tank Working Volume
50 gal.
100 gal.
100 gal.
CIP Flow & Pressure Application Size (Lines) Application Size (Vessels) Heating Capacity
12-45 gpm @ 50 psig
14-60 gpm @ 80 psig
14-60 gpm @ 80 psig
Up to 2”
Up to 2”
Up to 2”
Up to 4.5’ diameter
Up to 6’ diameter
Up to 6’ diameter
50 gal. / 20 °C to 65 °C / 22 minutes Allen Bradley CompactLogix PLC with PanelView +7
100 gal. / 20 °C to 65 °C / 10 minutes Allen Bradley CompactLogix PLC with PanelView +7
100 gal. / 20 °C to 65 °C / 10 minutes Allen Bradley CompactLogix PLC with PanelView +7
Controls
CLEAN-IN-PLACE SYSTEMS
FEATURES Standard • Supply tank – 316Lss / BPE SF2 designed for +14.5 psig/-14.7 psig (non-code) • Centrifugal supply pump w/ VFD – Fristam FPX • Pneumatic diaphragm valves – ITT Pure-Flo • Chemical and final rinse conductivity sensors • Radar tank level detection • Supply and return temperature sensors • Conduit – SCH40 PVC Coated Galvanized Steel • Frame – 304ss / 32 Ra welds color cleaned • Hygienic Piping – 316Lss / BPE SF2 • Steam & Condensate heating system (S60 / D60); Electric heating system (S45) • Return flow switch • Chemical injection system • UL, NEMA 4X Control Panel & Components • System Programming
Optional • Riboflavin Test • 10” PanelView • Mass Coriolis Flowmeter • Pressure Transmitter • Tank Vent Filter(s) • ASME Pressure Rated Tank(s) • Air Blow • Sample Valve • Electropolish (BPE SF4) • Piping Insulation • CIP Supply Routing Valve(s) • Drain Cooling or Routing Valves • Drain Pump • Sanitary Flex Hoses • Heating System Alternatives • SIP Function (S45 Only)
5
SYSTEM DIMENSIONS & WEIGHTS S45
S60
D60
Overall Size
90”L x 40”W x 85”H
74”L x 54”W x 90”H
112”L x 54”W x 90”H
Weight - Empty
1,750 lbs
1,850 lbs
2,300 lbs
Weight - Full
2,300 lbs
2,700 lbs
4,000 lbs
NOTE: System dimensions & weights may vary based on selected options.
DOCUMENTATION Standard
Optional
• Operation and maintenance manuals • Recommended spare parts (RSP) list • Mechanical Bill of Materials (BOM) • Instrumentation calibration procedures
• Functional Specifications (FS) • Configuration Specification (CS) • Factory Acceptance Test (FAT) • Site Acceptance Test (SAT)
• Material Test Reports (MTRs)
• Installation and Operation Qualification (IQ/OQ)
• Weld maps and weld logs (including qualification and inspection records) • Inspection test results, reports, and certificates
• Traceability matrix
• Instrument data sheets
• Component vendor documentation • As-built General Assembly (GA) drawings
• Borescope Inspection Video • Hydrostatic test certificate • Riboflavin spray coverage test
• As-built Process and Instrumentation Diagrams (P&ID)
• As-built electrical drawings • PLC & HMI code, I/O List
• Seismic zone anchorage calculations
GOOD TO KNOW • Designed to meet the requirements of ASME BPE SD-6.3 CIP Systems section. • Standardized, pre‑engineered CIP platform with ready‑to‑use P&IDs and layouts to reduce engineering time and minimize change orders. • Sani-Matic provides an industry leading FAT experience at its facility in Sun Prairie, WI.
CLEAN-IN-PLACE SYSTEMS
OPERATING REQUIREMENTS
TACTaFlow S60 / D60 Description
Requirement
Connection
Water #1 – Purified Water
20 gpm @ ≤ 40 psi, 20 °C - 80 °C
1.5” TC
Water #2 – WFI
20 gpm @ ≤ 40 psi, 20 °C - 80 °C
1.5” TC
Drain
≤ 60 gpm @ 20 °C - 80 °C
2.0” TC
Instrument Air
10 cfm @ 90 psig
0.5” FNPT
Steam Supply
450 lbs/hr @ 50 psig
1.0” Flange
Condensate Return
450 lbs/hr
1.0” Flange
30 Amp @ 460V AC, 3PH, 60 Hz (100A with Electric Heater option)
Electrical Supply
--
CIP Return (CIPR) (Optional)
10-60 gpm @ 30 psig
2.0” TC
TACTaFlow S45
Description
Requirement
Connection
Water #1 – Purified Water
20 gpm @ ≤ 20 psi, 20 °C - 80 °C
1.0” TC
Water #2 – WFI
20 gpm @ ≤ 20 psi, 20 °C - 80 °C
1.0” TC
Drain
≤ 45 gpm @ 20 °C - 80 °C
2.0” TC
Instrument Air
10 cfm @ 90 psig
0.5” FNPT
100 Amp @ 460V AC, 3PH, 60 Hz (30A with Steam Heat option)
Electrical Supply
--
NOTE: Operating requirements may vary based on selected options.
7
PURELY CLEAN Engineered for high purity pharmaceutical environments, our solutions deliver validated, repeatable cleaning you can trust. Designed to meet the most stringent hygienic and compliance standards, every system helps protect your product integrity.
2855 Innovation Way, Sun Prairie, WI 53590 sanimatic.com | hello@sanimatic.com | 800.356.3300
LOOKING FOR MORE INFORMATION? Scan the QR code to explore everything Sani-Matic has to offer.
B-0008.2
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8Powered by FlippingBook