S60
D60
S45
Model Overview
TACTaFlow S60
TACTaFlow D60
TACTaFlow S45 1 Tank CIP – Mobile
Design
1 Tank CIP
2 Tank CIP
Tank Working Volume CIP Flow & Pressure Application Size (lines) Application Size (vessels)
100 gal.
100 gal.
50 gal.
14-60 gpm @ 80 psig
14-60 gpm @ 80 psig
12-45 gpm @ 50 psig
Up to 2"
Up to 2"
Up to 2"
Up to 6' diameter
Up to 6' diameter
Up to 4.5' diameter
100 gal. / 20 °C to 65 °C / 10 minutes Allen Bradley CompactLogix PLC with PanelView +7
100 gal. / 20 °C to 65 °C / 10 minutes Allen Bradley CompactLogix PLC with PanelView +7
50 gal. / 20 °C to 65 °C / 22 minutes
Heating Capacity
Allen Bradley CompactLogix PLC with PanelView +7
Controls
Features
Standard Features • S upply tank – 316Lss / BPE SF2 designed for +14.5 psig/-14.7 psig (non-code)
• F rame – 304ss / 32 Ra welds color cleaned • H ygienic Piping – 316Lss / BPE SF2 • S team & Condensate heating system (S60 / D60) ; Electric heating system (S45) • Return flow switch • Chemical injection system • UL, NEMA 4X Control Panel & Components • System Programming
• C entrifugal supply pump w/ VFD – Fristam FPX • Pneumatic diaphragm valves – ITT Pure-Flo • C hemical and final rinse conductivity sensors • R adar tank level detection • S upply and return temperature sensors • C onduit – SCH40 PVC Coated Galvanized Steel Optional Features
• R iboflavin Test • 10" PanelView • Mass Coriolis Flowmeter • Pressure Transmitter • Tank Vent Filter(s) • ASME Pressure Rated Tank(s) • Air Blow • Sample Valve
• Electropolish (BPE SF4) • Piping Insulation • CIP Supply Routing Valve(s) • Drain Cooling or Routing Valves • Drain Pump • Sanitary Flex Hoses • Heating System Alternatives • SIP Function (S45 Only)
System Dimensions & Weights S60
D60
S45
Overall Size
74"L x 54"W x 90"H
112"L x 54"W x 90"H
90"L x 40"W x 85"H
Weight - Empty
1,850 lbs 2,700 lbs
2,300 lbs 4,000 lbs
1,750 lbs 2,300 lbs
Weight - Full
NOTE: System dimensions & weights may vary based on selected options.