TD-0008_SaniCab® PC_Technical Datasheet_Rev3.0

12.2.6 Exhaust Ducting Components The Exhaust Ducting Components are utilized to connect the exhaust fan outlet of the chamber and direct exhaust air to a suitable location (eg, through a roof penetration) The components are loose shipped and installed by others

Table 14: Exhaust Ducting Accessories

Informational Data

Accessory Name

Bend Radius

Diameter

Length

Description of Use

Exhaust Ducting – Elbow (90°) Exhaust Ducting – Elbow (45°) Exhaust Ducting – Straight (5')

12" Ø 12" Ø 12" Ø

N/A 180675" 90° transitions

N/A

145"

45° transitions

5"

N/A Straight run for round ducting

Exhaust Ducting – Seal Kit

(12" Ø)

N/A

N/A Gasket (EPDM) and hardware for all round ducting connections

NOTE: • All SaniCab PC exhaust and dryer connections are made through a shared 12" Ø connection

12.2.7 Service Panels Service Panels provide additional 304 stainless steel paneling around the front of the cabinet washer for separation of the side and rear maintenance space from the front operating area of the system Additional caulking and/or paneling to join the service panels to the installed area is required The Control Panel becomes front or remote mounted when this option is selected

NOTE: • This addition will not provide an airtight seal between the SaniCab PC and the surrounding structure

Service Panels Example (Shown on SaniCab P)

12.2.8 Buggy Inverter The Buggy Inverter accessory allows buggies to be inverted and placed onto a Custom Active Rack designed to clean buggies The transfer cart and rack are then transported to the SaniCab PC system for automated, thorough cleaning After being cleaned and unloaded from the cabinet, the Buggy Inverter reverts the buggy from the rack back onto the ground The Buggy Inverter is a loose ship, standalone skid with the following specifications: •  Framework

− Material: 304 stainless steel − Surface Finish: Bead blast − Maximum Buggy Weight: 110 lbs − Footprint Dimensions: 70" W x 70" L x 90" H − Foot Pad Dimensions: 17" L x 23" W

−  Allow for at least 6-feet clearance in front of the Buggy Inverter for Transfer Cart engagement with the system, along with at least 2-feet clearance behind the Buggy Inverter for Buggy engagement with the system − Right-hand or left-hand dump side design available − Stationary design with fixed base to reduce occupied floor space − Flexible buggy height coupling allows inversion of various sizes

Buggy Inverter

sanimatic.com 32

TD-0008.3