TD-0009_SaniTrend® Cloud DPR_Technical Datasheet_Rev2.0

Installation & Operating Requirements

• Control Panel Requirements - Installation of DPR Control Panel (NEMA 4X, 16” W x 20” H x 8” D) on frame or wall - 120V AC / 6 Amp Power - Broadband Internet Access (Ethernet/RJ45 or WiFi - WiFi requires optional WiFi access module) - DPR Reports Requires Hard Wired Running Signal or Communication (Ethernet/ RJ45) to Plant Equipment/Network for Running Signal* *NOTE: Equipment communicating to is required to be an Allen-Bradley CompactLogix TM or ControlLogix ® PLC Processor • Internet Browser (for SaniTrend Cloud online portal access) - Chrome (recommended) with Screen Size - 1920x1080 (recommended)

Hardware & Software Specifications

Component

Manufacturer

Model

Industrial PC / Edge Device

Allen-Bradley

Versaview 6300 ThingWorx SaaS

SaniTrend Cloud Online Portal

PTC

PLC

Allen-Bradley Allen-Bradley

Micro 820

HMI

Micro 800 LCD

WiFi Connection Package (Optional) Hardware Specifications

Component

Manufacturer

Model

Industrial Hotspot

Anybus

Wireless Bolt

Industrial Switch

Allen-Bradley

Bulletin 1783 Stratix 2000

(p sanimatic.com (f)

Sani-Matic, Inc.

(p (p) 800-356-3300

(f)

TD-0009.2

Powered by