DM-0014_Angle-Line Basket (ALB) Strainer_IOM_Rev2.0

Troubleshooting Table 3: Troubleshooting Problem

Possible Causes

Element won’t fit into housing

1. Damaged element

1. Incorrect element selected for particulate size 2. Damaged underlay 3. Damaged element 4. Loose assembly

Particulate getting through strainer

1. Element mesh/perforation size too small for particulate size/quantity typically present in process 2. Insufficient CIP pre-rinses 3. Inadequate Preventive Maintenance cleaning of strainer element

Strainer plugging frequently

1. Damaged pump impeller 2. Damage to upstream process equipment 3. Inadequate flushing of new installation

Metal particulates in strainer

1. Inspect End Cap for damage, specifically the four (4) “ears” that lock into place. 2. Ensure End Cap O-Ring is installed and not damaged. 3. Ensure End Cap O-Ring is lubricated.

End Cap Loose / Tight / Not Fitting

Hygienic Component Solutions Catalog For latest technical, part number, and spare parts information, see our latest catalog:

Hygienic Component Solutions Catalog

DM-0014_Angle-Line Basket (ALB) Strainer IOM_Rev2.0

5 of 5

Powered by