DM-0013_Digital Process Recorder (DPR)_IOM_Rev2.0

g. Facility Page – System Properties (Update Property Data)

Note (3)

Note (4)

Note (2)

Notes 1. Property Data is the term for the analog and digital values collected by the system.

2. Tag Name is the primary name of the process value. When changed here, it is changed within the SaniTrend Cloud online user portal and it is also changed on the DPR’s HMI panel display status screens. IMPORTANT NOTE – For DPR Reports, the tag name decides what tab to put the data in for the cycle reports. If the tag name does not contain any of the below text, it will not show up within the cycle report. a. “TEMP” – shows up in the “Temperature” tab b. “COND” or “_pH” or “pH” or “Volume” – shows up in the “Conductivity” tab c. “FLOW” – shows up in the “Flow” tab d. “PRESS” – shows up in the “Pressure” tab e. “LEVEL” – shows up in the “Level” tab f. IMPORTANT NOTE: Contact Sani-Matic if you have other properties not within the above parameters. 3. The units and min/max values for the properties are setup to be per system design at time of shipment (if this information is provided), but they can be modified here as needed. Note that this data, when updated, pushes to the cloud interface collection area and syncs with the DPR’s HMI Panel screen. 4. In addition, description text can be added that will show up for any additional details (e.g., tag #) desired to add to the system property. 5. NOTE: Property data cannot be added. When finished with updates, select “Apply Changes” to save.

DM-0013_Digital Process Recorder (DPR)_IOM_Rev2.0

51 of 56