Spate cleaner TANKO-SF
Dimensions
Picture 5.2-2: Dimensions
Connection for Pipe acc. to DIN 11866 Clipon Series A (DIN) Clipon Series B (ISO) Clipon Series C (ASME) Weldon Series A (DIN) Weldon Series C (ASME)
DN
s
H
h1
h2
d ø (mm)
RD ø (mm)
KD ø (mm)
Article No.
(mm)
(mm)
(mm)
(mm)
(mm)
665F441A16230
15
19.3
—
35
70
16
8
3.2
665F477A16230
15
21.6
—
35
70
16
8
3.2
665F490A16230
15
19.3
—
35
70
16
8
3.2
665F442A16630
20
23
1.5
35
70
17
—
—
25.4 (1")
665F491A16630
20
1.65
35
70
17
—
—
Table 5.2-2: Assignments of Dimensions
5.2.2 Installation Position
The device is designed for vertical installation, downward suspension or standing upwards, as the preferred position. In the event of a different installation position, observe the following: – The angle of deviation from the vertical should not exceed 25° in order to ensure the functioning of the device's self-cleaning feature. No compete cleaning is ensured when in standing upwards position
– The running performance may be compromised.
– The service life of the bearing elements may be shortened as a result of the increased strain.
– Maintenance intervals should be shortened if necessary (see section 7.4.1 Maintenance Intervals ).
26/63 Translation of the original Operating / Installation Instructions 2016/09 Rev.1
5 Installation
Powered by FlippingBook