TANKO® JM_IOM_Rev1

Jet Cleaner TANKO-JM

recommended minimum dimensions for the installation opening and for installing the device in the container and removing it from the container in assembled condition. A “ stationary device ” can be removed in different ways depending on the properties of the container and the size and accessibility of the installation opening. – Before removal, the downpipe [DP] is disconnected from the process connection [PC] and lifted out of the container through the installation opening from the outside, together with the device. The device is then disconnected from the downpipe [DP] at the media connection [MC] or – the device is disconnected from the downpipe [DP] at the media connection [MC] inside the container.

WARNING Risk of the device falling accidentally! The device may strike personnel when falling. There is a risk of severe physical injuries.  Hold the device firmly when installing/removing it.  There must be nobody beneath the device when installing/removing it.

NOTE No torque may be initiated into the device via the nozzles while the device is being installed/removed! Lever action can cause a torque to be transferred via the nozzle carrier to the bevel gear wheels. The threaded connections of the bevel gear wheels could become loose.  When setting the device down with the downpipe fastened in place, make sure that the nozzles ARE NOT under pressure due to the weight and length of the downpipe.  Clamp the downpipe in a vise so that the device can be fastened to the downpipe or loosened from it.

Interface A

The supply line for the cleaning agent must be disconnected at the media connection [MC] . The media connection [MC] is to be sealed with a screw cap.

For threaded connection (see Figure 5.2-7: Assembly of threaded connection (example JM100) ).

1. Undo the connection cover threaded connection (01) / media supply pipe with an open-end wrench or an adjustable pliers wrench.

2. Unscrew the device from the pipe for the media supply.

3. Provide the media connection [MC] with a suitable screw cap/sealing plug.

Interface B

NOTE Excessively small installation openings on the container! Risk of damage to the device or its surroundings.

 Before undoing the process connection [PC], check whether the device can be lifted out together with the cleaning head through the installation opening of the container (see section 3.3 Technical Data ).  The instructions for interface “ C ” must be observed if the installation opening is too small.

7 Maintenance

Translation of the original Operating / Installation Instructions 2016/12

51/90

Powered by