Jet Cleaner TANKO-JM

7.4.1.3 JM800 Maintenance Intervals

Maintenance points

A Media connection [MC] / Process connection [PC]

B Plain bearing on rotor shaft

C Plain bearing on rotor shaft

D Housing / bevel gear connection

E Nozzle carrier / nozzles connection

F Plain bearing on axis for nozzle carrier

G Nozzle carrier / bevel gear connection

Figure 7.4-3: JM800 maintenance points

The tightening torque values for the thread connections required for maintenance are listed in section 7.5.3 JM800 Spare Parts.