Jet Cleaner TANKO-MX

Interface C NOTE Excessively small installation opening for the container or components (e.g. agitators) in the container!! Nozzles collide during removal. Damage to the device. The nozzle carrier may come loose.  The nozzles must NOT collide! 1. Check the following before pulling the device out of the container: – The minimum dimension for the installation opening (see section 3.3 Technical Data ) and – Presence of interfering contours on surrounding components in the container. 2. Lift the device (downpipe [DP] with cleaning head) out of the container through the installation opening with the utmost care. 3. Or unscrew the cleaning head/device from the downpipe [DP] inside the container. NOTE “ Installation Opening – Stationary Device ”  Unfasten the cleaning head/device from the downpipe [DP] inside the container. – Provided that proper installation and assembly/removal of the cleaning head/device inside the container is assured.

7 Maintenance

Translation of the original operating/installation instructions 2016/03

47 / 86