TD-0001_COP Parts Washer_Technical Datasheet_Rev4.0

7.2 Circulation System Utilizing a recirculated design, the circulation system draws wash solutions from the tank and supplies solution back to the tank through tank jets or manifolds. • One (1) Manual butterfly valve for drain. See “Drain - Connection Size / Type” within Table 1 for valve size. • One (1) Centrifugal pump: − See Table 4 (below) for ratings − 316Lss wetted materials with EPDM elastomers − 3500 rpm motor − TEFC Motor (standard)

Table 4: Pump Data Tank Series and Length Ampco

HP

Pump Rating

Fristam Waukesha

gpm

psi

UW04 UW06 UW08

3.0 3.0 5.0 5.0

3.0 3.0 5.0 5.0

3.0 3.0 5.0 5.0

53

27

77

25 25

102

UW10

127

21

UW12

7.5

7.5

7.5

151

30

RW04 RW06 RW08 RW10 RW12 PW04 PW06 PW08

5.0 5.0

5.0 5.0

5.0 5.0

81

27

119

23

7.5

7.5

7.5

157

28 45 36 23 24 37 38 33 23 25

15.0 15.0

10.0 10.0

10.0 10.0

196

234

5.0

5.0

5.0

117

7.5

7.5

7.5

173

15.0 15.0 15.0

10.0 15.0 15.0

10.0 15.0 15.0

227

PW10

282 337

PW12

TW04 TW06 TW08 TW10 TW12

5.0

5.0

5.0

112

7.5

7.5

7.5

166

15.0 15.0 15.0

10.0 15.0 15.0

10.0 15.0 15.0

218

41

271

39 34

325

NOTE: • Pump rating data is based on Ampco pumps – ratings may change for other pump manufacturers.

7.3 Heating System Steam is directly injected into the wash solution to elevate its temperature. See Table 1 for load requirements, approximate heat up time, and connection size and type. • Steam supply manifold: − One (1) Self-regulating control valve that is single seated and has a SS/bronze body. The valve can control the wash solution temperature to a setting between 105–195 °F. Its thermobulb is mounted in a thermowell located in the tank’s sidewall. The thermowell has a bead blast, wetted finish. − One (1) Steam mixer located in the tank. The mixer has a bead blast ID / color cleaned OD finish.

sanimatic.com 8

TD-0001.4

Powered by