7.2 Circulation System Utilizing a recirculated design, the circulation system draws wash solutions from the tank and supplies solution back to the tank through tank jets or manifolds. • One (1) Manual butterfly valve for drain. See “Drain - Connection Size / Type” within Table 1 for valve size. • One (1) Centrifugal pump: − See Table 4 (below) for ratings − 316Lss wetted materials with EPDM elastomers − 3500 rpm motor − TEFC Motor (standard)
Table 4: Pump Data Tank Series and Length Ampco
HP
Pump Rating
Fristam Waukesha
gpm
psi
UW04 UW06 UW08
3.0 3.0 5.0 5.0
3.0 3.0 5.0 5.0
3.0 3.0 5.0 5.0
53
27
77
25 25
102
UW10
127
21
UW12
7.5
7.5
7.5
151
30
RW04 RW06 RW08 RW10 RW12 PW04 PW06 PW08
5.0 5.0
5.0 5.0
5.0 5.0
81
27
119
23
7.5
7.5
7.5
157
28 45 36 23 24 37 38 33 23 25
15.0 15.0
10.0 10.0
10.0 10.0
196
234
5.0
5.0
5.0
117
7.5
7.5
7.5
173
15.0 15.0 15.0
10.0 15.0 15.0
10.0 15.0 15.0
227
PW10
282 337
PW12
TW04 TW06 TW08 TW10 TW12
5.0
5.0
5.0
112
7.5
7.5
7.5
166
15.0 15.0 15.0
10.0 15.0 15.0
10.0 15.0 15.0
218
41
271
39 34
325
NOTE: • Pump rating data is based on Ampco pumps – ratings may change for other pump manufacturers.
7.3 Heating System Steam is directly injected into the wash solution to elevate its temperature. See Table 1 for load requirements, approximate heat up time, and connection size and type. • Steam supply manifold: − One (1) Self-regulating control valve that is single seated and has a SS/bronze body. The valve can control the wash solution temperature to a setting between 105–195 °F. Its thermobulb is mounted in a thermowell located in the tank’s sidewall. The thermowell has a bead blast, wetted finish. − One (1) Steam mixer located in the tank. The mixer has a bead blast ID / color cleaned OD finish.
sanimatic.com 8
TD-0001.4