7.2 CIRCULATION SYSTEM Utilizing a recirculated design, the circulation system draws wash solutions from the tank and supplies solution back to the tank through tank jets or manifolds. • One (1) Manual butterfly valve for drain. See Drain - Connection Size / Type within Table 1 for valve size. • One (1) Centrifugal pump: ο See Table 4 (below) for ratings ο 316Lss wetted materials with EPDM elastomers ο 3500 rpm motor ο TEFC Motor (standard)
TABLE 4: PUMP DATA
Pump Rating
Tank Series and Length
HP
gpm
psi
UW04 UW06 UW08 UW10 UW12 RW04 RW06 RW08 RW10 RW12 PW04 PW06 PW08 PW10 PW12 TW04 TW06 TW08 TW10 TW12
3.0 3.0 5.0 5.0 7.5 5.0 5.0 7.5
53 77
27 25 25 21 30 27 23 28 45 36 23 24 37 38 33 23 25 41 39 34
102 127 151
81
119 157 196 234 117 173 227 282 337 112 166 218 271 325
15.0 15.0
5.0 7.5
15.0 15.0 15.0
5.0 7.5
15.0 15.0 15.0
7.3 HEATING SYSTEM Steam is directly injected into the wash solution to elevate its temperature. See Table 1 for load requirements, approximate heat up time, and connection size and type. • Steam supply manifold ο One (1) Self-regulating control valve that is single seated and 316Lss wetted materials with bronze body components. The valve can control the wash solution temperature to a setting between 105–195 °F. Its thermobulb is mounted in a thermowell located in the tank’s sidewall. The thermowell has a bead blast, wetted finish. ο One (1) Steam mixer located in the tank. The mixer has a bead blast ID / color cleaned OD finish.
9
Powered by FlippingBook